DC/DC Converter
TEN 40WI Series, 40 Watt
•
High power density: 40W in
2”x2”x0.4” metal package
•
•
•
Ultra wide 4:1 input voltage range
•
•
•
•
Over temperature protection
•
•
Optional heat-sink
Very high efficiency up to 89 %
No minimum load required for single
output models
Under voltage lockout
Remote On/Off
Shielded metal case with insulated
baseplate
3-year product warranty
UL 62368-1 IEC 62368-1
The TEN 40WI series is a family of high performance 40W DC/DC converter
modules featuring ultra wide 4:1 input voltage ranges in a compact low profile
case with industry-standard footprint. A very high efficiency allows an operating
temperature range of –40°C to 85°C. Further standard features include remote
On/Off, output voltage trimming, over voltage protection, under voltage lockout, over temperature and short circuit protection. Typical applications for these
products are battery operated equipment and distributed power architectures
in communication and industrial electronics, everywhere where isolated, tightly
regulated voltages are required and space is limited on the PCB.
Models
Order Code
Input Voltage
Range
TEN 40-2410WI
TEN 40-2411WI
TEN 40-2412WI
TEN 40-2413WI
TEN 40-2422WI
TEN 40-2423WI
TEN 40-4810WI
TEN 40-4811WI
TEN 40-4812WI
TEN 40-4813WI
TEN 40-4822WI
TEN 40-4823WI
9 - 36 VDC
(24 VDC nom.)
18 - 75 VDC
(48 VDC nom.)
Output 1
Output 2
Vnom
Imax
3.3 VDC
5 VDC
12 VDC
15 VDC
+12 VDC
+15 VDC
3.3 VDC
5 VDC
12 VDC
15 VDC
+12 VDC
+15 VDC
10'000 mA
8'000 mA
3'330 mA
2'670 mA
1'670 mA
1'330 mA
10'000 mA
8'000 mA
3'330 mA
2'670 mA
1'670 mA
1'330 mA
Vnom
Efficiency
Imax
–12 VDC
–15 VDC
1'670 mA
1'330 mA
–12 VDC
–15 VDC
1'670 mA
1'330 mA
typ.
87 %
88 %
87 %
87 %
86 %
86 %
87 %
89 %
87 %
88 %
87 %
86 %
Options
TEN-HS3
- Optional Heat Sink: www.tracopower.com/products/ten-hs3.pdf
www.tracopower.com
September 20, 2023
Page 1 / 5
TEN 40WI Series, 40 Watt
Input Specifications
Input Current
24 Vin models: 75 mA typ. (3.3 Vout model)
95 mA typ. (5 Vout model)
50 mA typ. (12 Vout model)
50 mA typ. (15 Vout model)
60 mA typ. (12 / -12 Vout model)
70 mA typ. (15 / -15 Vout model)
48 Vin models: 55 mA typ. (3.3 Vout model)
60 mA typ. (5 Vout model)
30 mA typ. (12 Vout model)
25 mA typ. (15 Vout model)
30 mA typ. (12 / -12 Vout model)
30 mA typ. (15 / -15 Vout model)
24 Vin models: 1'680 mA typ. (3.3 Vout model)
2'000 mA typ. (5 Vout model)
2'000 mA typ. (12 Vout model)
2'000 mA typ. (15 Vout model)
2'000 mA typ. (12 / -12 Vout model)
2'000 mA typ. (15 / -15 Vout model)
48 Vin models: 840 mA typ. (3.3 Vout model)
1'000 mA typ. (5 Vout model)
1'000 mA typ. (12 Vout model)
1'000 mA typ. (15 Vout model)
1'000 mA typ. (12 / -12 Vout model)
1'000 mA typ. (15 / -15 Vout model)
24 Vin models: 50 VDC max. (100 ms max.)
48 Vin models: 100 VDC max. (100 ms max.)
24 Vin models: 7 VDC min. / 8 VDC typ. / 8.8 VDC max.
48 Vin models: 15 VDC min. / 16 VDC typ. / 17.5 VDC max.
24 Vin models: 8'000 mA (fast acting)
48 Vin models: 4'000 mA (slow blow)
(The need of an external fuse has to be assessed
in the final application.)
Internal Pi-Type
- At no load
- At full load
Surge Voltage
Under Voltage Lockout
Recommended Input Fuse
Input Filter
Output Specifications
Output Voltage Adjustment
Voltage Set Accuracy
Regulation
- Input Variation (Vmin - Vmax)
- Load Variation (0 - 100%)
Ripple and Noise
(20 MHz Bandwidth)
- Cross Regulation
(25% / 100% asym. load)
- single output
- dual output
±10% (By external trim resistor)
See application note: www.tracopower.com/overview/ten40wi
Output power must not exceed rated power!
±1% max.
single output models: 0.2% max.
dual output models: 0.2% max.
single output models: 0.5% max.
dual output models: 1% max. (Output 1)
1% max. (Output 2)
dual output models: 5% max.
3.3 Vout models:
5 Vout models:
12 Vout models:
15 Vout models:
12 / -12 Vout models:
15 / -15 Vout models:
50 mVp-p typ.
50 mVp-p typ.
75 mVp-p typ.
75 mVp-p typ.
120 / 120 mVp-p typ.
150 / 150 mVp-p typ.
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
September 20, 2023
Page 2 / 5
TEN 40WI Series, 40 Watt
Capacitive Load
- single output
3.3 Vout models:
5 Vout models:
12 Vout models:
15 Vout models:
12 / -12 Vout models:
15 / -15 Vout models:
3.3 Vout models:
5 Vout models:
12 Vout models:
15 Vout models:
12 / -12 Vout models:
15 / -15 Vout models:
- dual output
Minimum Load
- single output
- dual output
Temperature Coefficient
Start-up Time
Short Circuit Protection
Output Current Limitation
Overvoltage Protection
Transient Response
- Response Time
25'750 µF max.
13'600 µF max.
2'360 µF max.
1'510 µF max.
1'200 / 1'200 µF max.
750 / 750 µF max.
0 % of Iout max.
0 % of Iout max.
1.5 % of Iout max.
2 % of Iout max.
4 % of Iout max.
4 % of Iout max.
±0.02 %/K max.
20 ms max. (Power On)
20 ms typ. (Remote On)
Continuous, Automatic recovery
150% max. of Iout max.
118 - 125% of Vout nom.
(depending on model)
3.9 VDC typ. (3.3 VDC single model)
6.2 VDC typ. (5 VDC single model)
15 VDC typ. (12 VDC single model)
18 VDC typ. (15 VDC single model)
(By Zener diode)
250 µs typ. (25% Load Step)
Safety Specifications
Safety Standards
EN 60950-1
EN 62368-1
IEC 60950-1
IEC 62368-1
UL 60950-1
UL 62368-1
www.tracopower.com/overview/ten40wi
PD 2
Not mains connected
- IT / Multimedia Equipment
- Certification Documents
Pollution Degree
Over Voltage Category
EMC Specifications
EMI Emissions
- Conducted Emissions
- Radiated Emissions
External filter proposal:
EMS Immunity
- Electrostatic Discharge
Air:
Contact:
- RF Electromagnetic Field
- EFT (Burst) / Surge
Ext. input component:
- Conducted RF Disturbances
- PF Magnetic Field
Continuous:
1 s:
EN 55032 class A (with external filter)
EN 55032 class B (with external filter)
EN 55032 class A (with external filter)
EN 55032 class B (with external filter)
www.tracopower.com/overview/ten40wi
EN 55024 (IT Equipment)
EN 55035 (Multimedia)
EN 61000-4-2, ±8 kV, perf. criteria A
EN 61000-4-2, ±6 kV, perf. criteria A
EN 61000-4-3, 10 V/m, perf. criteria A
EN 61000-4-4, ±2 kV, perf. criteria B
EN 61000-4-5, ±1 kV, perf. criteria A
220 μF / 100 V / KY
EN 61000-4-6, 10 Vrms, perf. criteria A
EN 61000-4-8, 100 A/m, perf. criteria A
EN 61000-4-8, 1000 A/m, perf. criteria A
General Specifications
Relative Humidity
95% max. (non condensing)
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
September 20, 2023
Page 3 / 5
TEN 40WI Series, 40 Watt
Temperature Ranges
Power Derating
–40°C to +85°C
+105°C max.
–55°C to +125°C
Depending on model
See application note: www.tracopower.com/overview/ten40wi
110°C typ.
- Operating Temperature
- Case Temperature
- Storage Temperature
- High Temperature
Over Temperature
Protection Switch Off
Cooling System
Sense Function
- Protection Mode
Remote Control
- Voltage Controlled Remote
- Off Idle Input Current
- Remote Pin Input Current
Altitude During Operation
Switching Frequency
Insulation System
Isolation Test Voltage
Isolation Resistance
Isolation Capacitance
Reliability
Washing Process
Environment
- Input to Output, 60 s
- Input to Case, 60 s
- Output to Case, 60 s
- Input to Output, 500 VDC
- Input to Output, 100 kHz, 1 V
- Calculated MTBF
- Vibration
- Mechanical Shock
- Thermal Shock
Housing Material
Base Material
Potting Material
Pin Material
Pin Foundation Plating
Pin Surface Plating
Housing Type
Mounting Type
Connection Type
Footprint Type
Soldering Profile
Weight
Thermal Impedance
Natural convection (20 LFM)
10% max. of Vout nom.
(Sense line to be connected to the output either
at the module or at the load under regard of
polarity.)
On: 3.0 to 12 VDC or open circuit
Off: 0 to 1.2 VDC or short circuit
Refers to 'Remote' and '-Vin' Pin
10 mA typ. (24 Vin models)
5 mA (48 Vin models)
-0.5 to 0.5 mA
2'000 m max.
270 - 330 kHz (PWM)
300 kHz typ. (PWM)
Functional Insulation
1'600 VDC
1'600 VDC
1'600 VDC
1'000 MΩ min.
2'500 pF typ.
660'000 h (MIL-HDBK-217F, ground benign)
According to Cleaning Guideline
www.tracopower.com/info/cleaning.pdf
MIL-STD-810F
7.6 g, 3 axis, 60 min, 20-2000 Hz
MIL-STD-810F
40 g, 3 axis, half sine, 11 ms
MIL-STD-810F
Copper, Nickel plated
Non-conductive FR4 (UL 94 V-0 rated)
Epoxy (UL 94 V-0 rated)
Copper
Nickel (2 - 3 µm)
Tin (3 - 5 µm), matte
Metal Case
PCB Mount
THD (Through-Hole Device)
2" x 2"
Lead-Free Wave Soldering
265°C / 10 s max.
60 g
9.2 K/W typ.
7.6 K/W typ. (with Heat Sink)
- Case to Ambient
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
September 20, 2023
Page 4 / 5
TEN 40WI Series, 40 Watt
Environmental Compliance - REACH Declaration
www.tracopower.com/info/reach-declaration.pdf
REACH SVHC list compliant
REACH Annex XVII compliant
www.tracopower.com/info/rohs-declaration.pdf
Exemptions: 7a, 7c-I
(RoHS exemptions refer to the component
concentration only, not to the overall
concentration in the product (O5A rule).)
06f84086-a617-4784-8f19-b4cc039f9b17
- RoHS Declaration
- SCIP Reference Number
Supporting Documents
Overview Link (for additional Documents)
www.tracopower.com/overview/ten40wi
Outline Dimensions
15.24
22.9
(0.6)
2.5
6
5
4
(2.0)
(Ø0.04)
7
Ø1.0
8
50.8
Bottom view
(1.8)
1
45.72
2
(0.1)
(0.2)
3
Pinout
(0.9)
5.08
Pin
Single
Dual
1
+Vin (Vcc)
+Vin (Vcc)
2
–Vin (GND)
–Vin (GND)
3
Remote On/Off
Remote On/Off
4
–Sense*
+Vout
5
+Sense*
Common
6
+Vout
Common
7
–Vout
–Vout
8
Trim
Trim
*Sense line to be connected to the output
either at the module or at the load under
7.62
7.62
17.78
(0.3)
(0.3)
(0.7)
5.08
5.08
(0.2)
(0.2)
50.8
(2.0)
5.6
10.2
(0.22)
(0.4)
regard of polarity.
Dimensions in mm (inch)
Tolerance: x.xx ±0.05 (x.x ±0.02)
Tolerance: x.xxx ±0.25 (x.xx ±0.01)
Pin dimension tolerance ±0.10 (0.004)
© Copyright 2023 Traco Electronic AG
Specifications can be changed without notice.
www.tracopower.com
Rev. September 20, 2023